Multifunkčný filter HydroTreat ECONOMY 1.2 s hmotou Ecomix P
Catalog code: E1035EP/HYS1
HydroTreat ECONOMY 1.2 with Ecomix P – multifunctional filter for well water treatment
Central solution for well water treatment without compromises
The multifunctional filter HydroTreat ECONOMY 1.2 with Ecomix P filter media is a compact, fully automatic device designed for comprehensive treatment of well water.
Devices with Ecomix filtration material are water treatment systems that remove iron, manganese, ammonium ions, organic impurities, and simultaneously soften water in a single filtration unit.
This model is suitable for water with a low content of organic substances and ensures stable quality of treated water even with fluctuations in input parameters.
Why choose HydroTreat ECONOMY with Ecomix P material
- Comprehensive solution in one - removal of iron, manganese, ammonium ions, organic impurities, and softening of hard water.
- Stable water quality even with parameter fluctuations - filtering material Ecomix P is suitable for treating water with a moderate content of organic substances. It easily adapts to significant seasonal changes in water composition without fluctuations in the quality of the treated water.
- Pure water without a metallic taste and odor - improves the color of the water, eliminates unpleasant smells, and ensures a pleasant taste.
- Completely automatic operation without worries - the device is pre-set and does not require programming after installation.
- Economical regeneration with low salt consumption, which takes place at any time according to the customer's needs (usually at night around 2:00 AM).
- Without the supply of untreated water during regeneration - the device does not supply raw water to the system during the regeneration cycle.
- System safety and protection - overflow protection, protective tube, and salt grid increase operational reliability.
- Compact solution - space-saving design.
What is Ecomix P material?
The multifunctional filtration material Ecomix P is a multi-component filtering material designed for the treatment of problematic well or tap water with low organic content. It helps achieve clean, soft, and well-treated water for everyday use.
The Ecomix filter media is regenerated with saltthat needs to be monitored to ensure that a sufficient amount is available for regeneration purposes. Regeneration occurs automatically through the control head – the device draws in and flushes the salt solution. In typical sizing, regeneration is estimated to occur approximately once a week, and it is important to know the water hardness and the maximum hourly and monthly consumption for the proper filter size design.
Technical parameters
- Size and type of connection: 1" external thread
- Flow capacity: 1.0 – 1.2 m³/h
- Min. required flushing: 0.75 m³/h
- Filter area: 0.05 m2
- Quantity and type of material: 25 l, Ecomix P
- Brine reservoir: built-in
- Dimensions (H×W×D): 1080 × 320 × 500 mm
- Weight (dry, without salt): 33.3 kg
Rýchlosti prúdenia
- Operation: 20–25 m/h
- Backwashing: 10–15 m/h
- Regeneration: 3–5 m/h
Regeneration consumption
- Salt consumption/regeneration: ~100 g/1 l Ecomix
- Water consumption/regeneration: <10 l/1 l Ecomix
Operating conditions and requirements for source water
- Optimal bed height: 800 mm
- Minimum bed height: 500 mm
- Free content: ≥ 40% of the bed height
- Total Dissolved Solids (TDS): ≤ 4000 mg/l
- Water temperature: 4–40 °C
- pH range: 5.0–9.0
- Hardness (CaCO₃): ≤ 750 mg/l ≈ 42 °dH
- Iron: ≤ 15 mg/l
- Manganese: ≤ 3 mg/l
- CHSK-Mn (KMnO4): ≤ 3 mg/l
- Ammonium ions: ≤ 0.0 mg/l
- Chlorine: ≤ 0.5 mg/l
We recommend
- We recommend installing before the water softener mechanical pre-filterthat prevents the entry of floating impurities (sand, rust, clay, etc.) that could damage the mechanical components of the softening device.
- To choose the right size, you need to to know the hardness of waterthe peak hourly and average monthly water consumption, and last but not least, also take into account other values such as iron, manganese, ammonia, and organic water pollution. To do this, it is essential to have, or perform a water analysis.