Skip to Content

What a basic (final) water analysis shows – and what it does not

The basic or so-called acceptance water analysis does not provide an answer to the question of whether the water contains any undesirable substances. The result describes a specific sample taken and the specific indicators that the laboratory examined.

If all tested indicators meet the relevant requirements, it means that the sample was compliant in these indicators. It cannot be automatically concluded that all possible chemical or microbiological risks have been examined.

When analyzing water, the result is not the only important factor. It is equally important to know what was investigated, how the sample was collected, and what purpose the protocol is intended to serve.

What is meant by "final water analysis"?

The term "acceptance analysis" is used in practice for laboratory testing of water, which is intended to demonstrate its quality in a specific official or construction process. However, it is not appropriate to understand it as a single universal laboratory package with the same scope in all cases.

The requirements for the quality of drinking water in Slovakia are primarily regulated by Act No. 355/2007 Coll. and the Decree of the Ministry of Health of the Slovak Republic No. 91/2023 Coll. The law distinguishes between different types of limit values and also regulates the conditions for the monitoring and sampling of drinking water.

If the protocol is to be used for final inspection, proceedings before a public health authority, or another official purpose, it is advisable to verify the exact required scope of examination and method of sampling before ordering the analysis. Not every commercial package labeled as a "basic analysis" must automatically meet the requirements of a specific proceeding.

What can be reliably determined from the results of the analysis

The laboratory protocol allows to determine:

  • which indicators were investigated in the sample,
  • what values were measured,
  • in what units are the results presented,
  • whether the measured value meets the relevant limit or other value, if it applies to the given indicator,
  • from which location and when the sample was taken, if this information is correctly stated in the documentation.

Law No. 355/2007 Coll. distinguishes between the maximum permissible value, the permissible value, and the recommended value in the quality of drinking water. Their significance is not the same, so it is not enough to just look at whether the number in the laboratory report is marked as compliant or non-compliant.

What does it mean if the analysis is satisfactory

If the laboratory sample met all tested parameters, the correct conclusion is:

The sample met the requirements at the time of collection based on the tests performed.

This resolution is important.

A satisfactory basic analysis does not automatically mean that:

  • The laboratory tested all possible chemical substances,
  • all possible microorganisms were tested,
  • the water quality will be the same in a few months,
  • the water level is the same at every outlet in the house,
  • water cannot later be affected by a well, plumbing, a reservoir, or water treatment.

Especially with a private source, the result can be influenced by the condition of the well, the weather, the operation of the source, repairs, flooding, shutdowns, or changes in the surrounding environment.

What a basic water analysis may not include

The scope of laboratory testing is not unlimited. If a specific parameter was not ordered and the laboratory did not test it, no conclusion about its concentration can be drawn from the report.

This applies, for example, to substances or groups of substances that are examined specifically based on particular risks, locations, previous results, or the purpose of the analysis.

Therefore, it is important to distinguish:

“the substance was not detected in the sample”

from

“this substance was not the subject of testing.”

They are two completely different pieces of information.

Even microbiological analysis does not test all possible microorganisms

In microbiological testing, specific indicators listed in the scope of the examination are monitored. Therefore, the result should be interpreted based on which microbiological indicators were actually tested.

The negative result of selected indicators cannot be interpreted as a statement that the laboratory has proven the absence of all possible pathogens.

In microbiological analysis, the correct sampling, appropriate container, site of collection, handling of the sample, and its transportation to the laboratory are additionally extremely important.

Why sample collection matters

Even high-quality laboratory measurements can describe a different situation than the one we want to assess if the sample was taken from an inappropriate location or in an inappropriate manner.

When interpreting, one should know, for example:

  • whether it is water directly from the well or from the internal plumbing,
  • whether the sample was taken before or after the water treatment device,
  • whether the water had stagnated for a longer period before sampling,
  • whether the well or pipe was disinfected shortly before sampling,
  • for what purpose the result is used.

In official assessments, a self-collected indicative sample cannot be automatically confused with a sample taken in the manner required for the specific purpose.

According to the current wording of § 17 of Act No. 355/2007 Coll., the sampling of drinking water is carried out in an accredited manner according to the requirements of the technical standard or by a qualified person under the conditions set by law.

If you need the result for official purposes, please order it.  water analysis with sample collection to the extent appropriate for the specific proceedings.

When might a broader or targeted analysis be necessary

The scope of the examination should be based on what you need to find out.

A broader or targeted examination may be appropriate, for example, when:

  • the previous result showed a problem,
  • the water changed color, taste, or smell,
  • there was a flood or damage to the well,
  • the source was out of service for a longer period,
  • there is a specific potential source of pollution in the area,
  • preparation of a technology proposal for well water treatment,
  • it is necessary to check the result after the adjustment or corrective action has been made.

The analysis should not be chosen solely based on the package name. The crucial question is what you need to verify with the results.

In an orientation check without an official purpose, it can also be a practical option to do a  water analysis with self-sampling, as long as the laboratory procedure is followed and the chosen range corresponds to what you want to find out.

What to do if any indicator is not satisfactory

An unsatisfactory result alone does not determine the correct water treatment technology.

First, it is necessary to find out:

  1. which indicator does not meet the requirements,
  2. what value was measured and in what unit,
  3. from what location the sample was taken,
  4. whether it is raw or already treated water,
  5. or the result may be related to the source, distribution, or existing equipment,
  6. what other data is needed to determine the cause.

Only then does it make sense to assess the appropriate way of remedying the situation.

When it comes to well water, the treatment design should not be based solely on one number. The choice of technology may also depend on pH, other water indicators, desired flow rate, consumption, and operating conditions.

One result is not a permanent characteristic of the well

Spring water is a private source whose quality can change over time. Therefore, one satisfactory result cannot be understood as a permanent confirmation of the source's condition.

A new or control analysis should be considered especially after an event that could have affected water quality, or if its appearance, smell, taste, or operational conditions of the source change.

A universal interval suitable for every well does not exist. The frequency of monitoring should be based on the way water is used, previous results, and the risks of the specific source.

How to read the result correctly

For each protocol, check four things:

1. What kind of water was taken?

From the well, from the faucet, before treatment or after the device?

2. When and how was the sample collected?

The result pertains to a specific moment and method of collection.

3. What was the laboratory actually testing?

The decisive factor is the list of indicators in the protocol, not the name of the package.

4. What purpose do you need the result for?

Preliminary assessment of water, proposal for modification, and administrative proceedings may not require the same extent or method of sampling.

Key rule

A satisfactory analysis means that a specific sample met the tested parameters. It does not mean that the laboratory checked all possible substances and all possible risks of the water.

If the result is to be used for official purposes, first verify the required scope and method of sampling. If it is to be used for water treatment design, the scope of the examination should be adapted to the water source and the issue that needs to be addressed.

Editorial Office Danum s.r.o