Skip to Content

Why is it risky to choose equipment without water analysis

Color, odor, turbidity, or limescale can indicate a water problem, but they alone are not sufficient for selecting the right technology. The same symptom can have multiple causes, and a device chosen without the necessary data may not solve the problem or may operate under unsuitable conditions.

Water from the well is therefore one of the basic foundations of the current  water analysis. With water from the public water supply, the need for further measurement depends on what we want to address – whether it is a specific problem with water quality, or for example just hardness, taste, or comfort of use..

The same symptom can have multiple causes

The appearance and behavior of water are useful signals, but they are not a diagnosis.

Brownish coloration may be related to iron, sediment, or the condition of the plumbing. The odor may originate from the source itself, from hot water, pipes, or from a section of the plumbing that has not been used for a long time. Deposits on fixtures are often related to water hardness, but the limescale itself says nothing about microbiological quality or other dissolved substances.

Even clear, odorless water can contain substances or microorganisms that we cannot detect with our senses.

Therefore, it is risky to proceed in this manner:

symptom → device

The safer procedure is:

symptom → possible causes → measurement → interpretation → appropriate type of solution

What we do not know without analysis and input data

A water analysis will only show the indicators that have actually been analyzed. Therefore, it is important to select its scope according to the water source, the purpose of the result, and the issue we need to verify.

When designing water treatment, it is not enough to know just the laboratory values. Additional data may also be necessary:

  • water source – public water supply, well, or other source,
  • purpose of treated water,
  • daily consumption,
  • required peak flow,
  • water pressure,
  • number of collection points,
  • assembly space,
  • availability of waste and electricity,
  • existing devices and their condition.

Without this information, it is often possible to determine the general principle of adjustment, but not to reliably design a specific capacity and configuration.

What can happen with the wrong device selection

The improperly chosen technology may not yield the expected result, even if the device itself is technically functional.

The problem will remain unresolved

If only the visible symptom is addressed, the actual cause may remain undetected. Mechanical filtration, for example, addresses captureable particles, but on its own does not resolve dissolved substances or microbiological contamination.

The device can operate in unsuitable conditions

The effectiveness of many technologies depends on the quality of the input water, pH, flow rate, pressure, or the presence of other substances. Conditions suitable for one type of water may not be suitable for another.

The capacity may be incorrect

Equipment sized only according to the number of people may be insufficient during high instantaneous demand. Conversely, unnecessarily large equipment can increase investment or operating costs without any real benefit.

A false sense of security may arise

Just because water has passed through a filter or another device does not automatically mean it meets all indicators. The result of the treatment is verified by measurement or a control analysis in relevant issues.

A well and a public water supply are not the same case

When designing a treatment, it is always necessary to know where the water comes from.

Water from the well

The quality of a private water source can change, and the operator of the public water supply does not continuously monitor it on behalf of the well owner. If the water is to be used for drinking or if a treatment technology is proposed based on the results, a current analysis is a crucial basis.

The scope of the analysis should be chosen according to the purpose and local conditions. One basic package of examinations may not answer every question.

Water from the public water supply

In the case of public water supply, the situation is different. The supplied water is subject to a control system according to the applicable requirements for drinking water.

However, this does not mean that laboratory measurement is never meaningful. It can be appropriate, for example, when there is suspicion of a problem in the internal distribution systems, during an unusual change in water, or if we need specific data for technology design.

If a household is only addressing a comfort issue, such as water hardness, the same extent of analysis may not automatically be necessary as with unknown well water.

Correct order of decision-making

When treating water, it is advisable to proceed in several steps.

1. Define the problem and the goal

First, we need to know what we want to change. A different solution may be necessary for drinking water in the kitchen and another for protecting the entire house.

2. Obtain the necessary measurements

In the case of well water, it usually involves a current analysis of the water. For a specific problem, it may be necessary to add another indicator or measurement.

3. Correctly interpret the results

One value is not assessed in isolation. The significance of the result may depend on other parameters, the source of water, and the purpose of use.

4. Complete operational data

Flow, pressure, consumption, and installation location determine what capacity can be realistically used.

5. Only then choose the type of solution

The technology should be selected based on the specific problem and conditions, not based on the number of filtration stages or the general designation of the product.

6. Verify the result

After treatment, it makes sense to check whether the desired result has been achieved in relevant issues. The method of checking depends on the treatment performed and the purpose of the water.

When the analysis alone is not enough

The laboratory protocol describes the properties of the analyzed sample, but does not propose a device.

Two households may have similar analysis results but different consumption, pressure, number of bathrooms, or available space. Therefore, the same technology may not have the same size or the same configuration.

Before a specific proposal, it is advisable to know especially:

  • the entire analysis protocol,
  • place and date of collection,
  • information on whether it is raw or already treated water,
  • daily consumption and peak flow,
  • available pressure,
  • pipe dimension,
  • space for equipment,
  • possibility of connection to sewage and electricity,
  • the desired result of the adjustment.

If some data is missing, the proposal may only be indicative.

First identify the problem, then choose a solution

Water analysis is not a formality before purchasing equipment. It is one of the documents that helps determine what needs to be addressed in the water and what does not need to be addressed.

For well water, current measurements should be the basis of the proposal. For water from the public water supply, it is necessary to first determine whether we are addressing water quality, the condition of the household plumbing, or just comfort.

Only when we understand the problem, the necessary measurements, and the operating conditions does it make sense to decide on a specific technology and its capacity.

Danum s.r.o.